1993 Subaru SVXFACTORY OEM SERVICE PROCEDURE

Code 35: Purge Control Solenoid Valve

NOTE: Refer to illustration for ECU connector and terminal identification. See Figure .
  1. Turn ignition switch to ON position. Using a DVOM, check voltage between ECU connector B62, terminal No. 14 (backprobe) and ground. Voltage should be 10 volts or greater. If voltage is not as specified, go to next step. If voltage is as specified, go to step 4).
  2. Turn ignition switch to OFF position. Disconnect ECU and main relay connectors. Using an ohmmeter, check resistance between ECU connector B62, terminal No. 14 and main relay connector terminal No. 4 (Yellow wire). Resistance should be zero ohms. If resistance is as specified, go to next step. If resistance is not as specified, repair circuit as necessary.
  3. Turn ignition switch to ON position. Using a DVOM, check voltage between ground and main relay connector terminals No. 1 (Black/White wire) and No. 2 (Brown/Black wire). Voltage should be 10 volts or greater at each terminal. If voltage is as specified, replace main relay. If voltage is not as specified, repair appropriate circuit as necessary.
  4. Turn ignition switch to ON position. Using a DVOM, check voltage between ECU connector B62, terminal No. 6 (backprobe) and ground. Voltage should be 7 volts or greater. If voltage is not as specified, go to next step. If voltage is as specified, check ECU connector terminals for good contact. Repair as necessary. If connector terminals are okay, replace ECU.
  5. Turn ignition switch to OFF position. Remove collector and disconnect purge control solenoid valve connector. Using an ohmmeter, check resistance between ECU connector B62, terminal No. 6 and solenoid valve connector terminal No. 2 (White/Red wire). Resistance should be zero ohms. If resistance is as specified, replace purge control solenoid valve. If resistance is not as specified, repair circuit as necessary.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.