1988 Subaru XT DLFACTORY OEM SERVICE PROCEDURE

THERMO Vacuum Valve

  1. Remove valve from intake manifold. Connect hoses to ports for air cleaner and EGR valve (2 upper ports) and plug port to canister (lower port). Submerge valve into a container of cold water.
    NOTE: DO NOT allow water to enter valve.
  2. Heat water slowly. Blow air into valve and confirm valve opens or closes in response to water temperature.
  3. Thermo vacuum valve should be completely open below 86°F (30°C) and should completely close above 104°F (40°C). Remove thermovalve from water. Connect hoses to vacuum valve EGR valve port and canister port, and plug port to air cleaner.
  4. Blow air into valve and confirm that valve opens and closes in response to water temperature. Valve should completely open below 86°F (30°C) and should completely close above 104°F (40°C).
Fig 1: Sectional View of EGR Vacuum Valve & Check Valve
G67259Courtesy of SUBARU OF AMERICA, INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.