2012 Scion xD L4-1.8L (2ZR-FE)FACTORY OEM SERVICE PROCEDURE

Removal





2ZR-FE IGNITION: IGNITION COIL AND SPARK PLUG: REMOVAL

1. REMOVE NO. 2 CYLINDER HEAD COVER

(a) First, lift up the rear of the No. 2 cylinder head cover to disengage the 2 fittings shown in the illustration.

Factory service manual diagram




(b) Next, lift the front of the No. 2 cylinder head cover to disengage the 2 fittings shown in the illustration. Then remove the No. 2 cylinder head cover.

NOTICE:
* Ensure that the rubber grommets remain attached to the No. 2 cylinder head cover.
* If any grommets are attached to the bolts, move them to the No. 2 cylinder head cover.

Factory service manual diagram




2. REMOVE IGNITION COIL ASSEMBLY

(a) Disconnect the camshaft timing oil control valve connector.

Factory service manual diagram




(b) Disconnect the 4 ignition coil connectors.

Factory service manual diagram




(c) Remove the 4 bolts and 4 ignition coils.

3. REMOVE SPARK PLUG

(a) Remove the 4 spark plugs.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.