2012 Scion xD Automatic TransFACTORY OEM SERVICE PROCEDURE

Valve Body Assembly: Reassembly: Reassembly

  1. REMOVE MANUAL VALVE 
    1. Coat the manual valve with Toyota Genuine ATF WS or equivalent, and install it to the valve body.
      Fig 1: Identifying Manual Valve
      GTY166722Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSTALL NO. 3 SOLENOID LOCK PLATE 
    1. Install the shift solenoid valve SLT to the valve body.
      Fig 2: Identifying Solenoid Lock Plates & Valves
      GTY166575Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *1 No. 1 Solenoid Lock Plate
      *2 No. 3 Solenoid Lock Plate
      *3 Shift Solenoid Valve ST
      *4 Shift Solenoid Valve SLT
    2. Install the No. 1 solenoid lock plate to the shift solenoid valve SLT.
    3. Install the shift solenoid valve ST to the valve body.
    4. Install the No. 3 solenoid lock plate to the valve body with the 2 bolts.

      Torque: 11 N*m (110 kgf*cm, 8 ft.*lbf) 

  3. INSTALL SHIFT SOLENOID VALVE SLU 
    1. Install the shift solenoid valve SLU onto the valve body.
      Fig 3: Identifying Solenoid Lock Plate
      GTY166142Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *1 Solenoid Lock Plate
    2. Install the solenoid lock plate with the bolt.

      Torque: 11 N*m (110 kgf*cm, 8 ft.*lbf) 

  4. INSTALL SHIFT SOLENOID VALVE S2 
    1. Install the shift solenoid valve S2 to the valve body with the bolt.
      Fig 4: Locating Shift Solenoid Valve S2 Bolt
      GTY165664Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Torque: 11 N*m (110 kgf*cm, 8 ft.*lbf) 

  5. INSTALL SHIFT SOLENOID VALVE S1 
    1. Install the shift solenoid valve S1 to the valve body with the bolt.
      Fig 5: Locating Shift Solenoid Valve S1 Bolt
      GTY165897Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Torque: 11 N*m (110 kgf*cm, 8 ft.*lbf) 

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.