2012 Scion tC L4-2.5L (2AR-FE)FACTORY OEM SERVICE PROCEDURE

Control Assembly: Testing and Inspection





HEATING / AIR CONDITIONING: AIR CONDITIONING PANEL: INSPECTION

1. INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY

Factory service manual diagram




(a) Check the heater control resistance.

(1) Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.

Standard Resistance:

Factory service manual diagram




If the result is not as specified, replace the No. 1 heater control sub-assembly.

Text in Illustration

Factory service manual diagram




(b) Check the F/R indicator operation.

(1) Connect the positive (+) lead from the battery to terminal 2 (A/C+) and the negative (-) lead to terminal 4 (REC).

(2) Push the F/R switch in and check that the indicator lights up.

Standard:

Indicator lights up

If the result is not as specified, replace the heater control.

(c) Check the illumination operation.

(1) Connect the positive (+) lead from the battery to terminal 7 (ILL+) and the negative (-) lead to terminal 6 (ILL-) and check that the bulb illuminates.

Standard:

Bulb illuminates

If the result is not as specified, replace the bulb.

2. INSPECT NO. 2 HEATER CONTROL SUB-ASSEMBLY

Factory service manual diagram




(a) Check the heater control resistance.

(1) Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.

Standard Resistance:

Factory service manual diagram




If the result is not as specified, replace the No. 2 heater control sub-assembly.

Text in Illustration

Factory service manual diagram




(b) Check the illumination operation.

(1) Connect the positive (+) lead from the battery to terminal 7 (ILL+) and the negative (-) lead to terminal 1 (ILL-) and check that the bulb illuminates.

Standard:

Bulb illuminates

If the result is not as specified, replace the bulb.

(c) Check the Rr. DEF indicator operation.

(1) Connect the positive (+) lead from the battery to terminal 3 (IG) and the negative (-) lead to terminal 5 (E).

(2) Push the Rr. DEF switch in and check that the indicator lights up.

Standard:

Indicator lights up

If the result is not as specified, replace the No. 2 heater control sub-assembly.

3. INSPECT NO. 3 HEATER CONTROL SUB-ASSEMBLY

Factory service manual diagram




(a) Check the heater control knob resistance.

(1) Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.

Standard Resistance:

Factory service manual diagram




If the result is not as specified, replace the No. 3 heater control sub-assembly.

Text in Illustration

Factory service manual diagram




(b) Check the A/C indicator operation.

(1) Connect the positive (+) lead from the battery to terminal 2 (A/C+) and the negative (-) lead to terminal 4 (REC).

(2) Push the A/C switch in and check that the indicator lights up.

Standard:

Indicator lights up

If the result is not as specified, replace the No. 3 heater control sub-assembly.

(c) Check the illumination operation.

(1) Connect the positive (+) lead from the battery to terminal 5 (ILL+) and the negative (-) lead to terminal 6 (ILL-) and check that the bulb illuminates.

Standard:

Bulb illuminates

If the result is not as specified, replace the bulb.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.