2006 Scion xA StandardFACTORY OEM SERVICE PROCEDURE

Monitor Description

While the engine being cranked, the positive battery voltage is applied to terminal STA of the ECM. If the ECM detects the Starter Control (STA) signal while the vehicle is being driven, it determines that there is a malfunction in the STA circuit. The ECM then illuminates the MIL and sets the DTC. This monitor runs when the vehicle is driven at 20 km/h (12.4 mph) for over 20 seconds.

DTC DETECTION CONDITION CHART

DTC No. DTC Detection Condition Trouble Area
P0617 When conditions (a), (b) and (c) met when battery (+B) voltage 10.5 V or more applied for 20 seconds (1 trip detection logic):
  1. Vehicle speed greater than 12.4 mph (20 km/h)
  2. Engine revolution greater than 1,000 rpm
  3. STA signal ON

  • Park/Neutral Position (PNP) switch switch (A/T)(1)
  • Clutch start switch (M/T)*
  • ST relay circuit
  • ECM
(1) A/T denotes Automatic Transaxle models and M/T denotes Manual Transaxle models.