Fuel Pump Control Circuit: Wiring Diagram
- PERFORM ACTIVE TEST USING INTELLIGENT TESTER (OPERATION OF CIRCUIT OPENING RELAY)Â
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Enter the following menus: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / FUEL PUMP/SPD.
- Check whether operating sounds can be heard while operating the relay using the tester.
OK:Â
Operating sounds can be heard from relay.Â
OK : GO TO STEP Â Â 7Â
NGÂ
- INSPECT ECM POWER SOURCE CIRCUITÂ
NG : REPAIR OR REPLACE POWER SOURCE CIRCUITÂ
OK : Go to next StepÂ
- INSPECT CIRCUIT OPENING RELAY (Marking: C/OPN)Â
- Disconnect the 1A, 1B, 1D and 1E instrument panel junction block connector.
- Measure the resistance of the circuit opening relay.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 1B (11) - 1A (8) 10 kΩ or higher 1B (11) - 1A (8) Below 1Ω (when battery voltage is applied to terminals 1E (5) and 1D (1)) NG : REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLYÂ
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK : Go to next StepÂ
- INSPECT ECM (FC VOLTAGE)Â
- Turn the ignition switch ON.
- Measure the voltage of the ECM connectors.
standard voltageÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition FC (E4-10) - E1 (E6-1) 9 to 14 V OK : REPLACE ECMÂ
NGÂ
- CHECK WIRE HARNESS (IGNITION SWITCH - CIRCUIT OPENING RELAY (Marking: C/ OPN))Â
- Disconnect the I5 ignition switch connector.
- Disconnect the 1F instrument panel junction block connector.
- Measure the resistance of the wire harness side connectors.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition IG2 (I5-6) - Instrument panel junction block (1F-4) Below 1 Ω IG2 (I5-6) or Instrument panel junction block (1F-4) - Body ground 10 kΩ or higher NG : REPAIR OR REPLACE HARNESS AND CONNECTORÂ
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK : Go to next StepÂ
- CHECK WIRE HARNESS (ECM - CIRCUIT OPENING RELAY)Â
- Disconnect the E4 ECM connector.
- Disconnect the 1E instrument panel junction block connector.
- Measure the resistance of the wire harness side connectors.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition FC (E4-10) - Instrument panel junction block (1E-5) Below 1 Ω FC (E4-10) or Instrument panel junction block (1E-5) - Body ground 10 kΩ or higher NG : REPAIR OR REPLACE HARNESS AND CONNECTORÂ
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK : REPLACE ECMÂ
- INSPECT FUEL PUMPÂ
- Inspect the fuel pump (see INSPECTION ).
NG : REPLACE FUEL PUMPÂ
OK : Go to next StepÂ
- CHECK WIRE HARNESS (FUEL PUMP - CIRCUIT OPENING RELAY (C/OPN), BODY GROUND)Â
- Disconnect the 1A instrument panel junction block connector.
- Disconnect the F9 fuel pump connector.
- Measure the resistance of the wire harness side connectors.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition Instrument panel junction block (1A-8) - Fuel pump (F9-4) Below 1 Ω Fuel pump (F9-5) - Body ground Below 1 Ω Instrument panel junction block (1A-8) or Fuel pump (F9-4) - Body ground 10 kΩ or higher NG : REPAIR OR REPLACE HARNESS AND CONNECTORÂ
OK : CHECK AND REPAIR HARNESS AND CONNECTOR (EFI RELAY - CIRCUIT OPENING RELAY)Â
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.