2005 Scion xB AutomaticFACTORY OEM SERVICE PROCEDURE

Data List/Active Test

  1. DATA LIST 

    HINT:

    According to the DATA LIST displayed by the OBD II scan tool or hand-held tester, you can read the value of the switch, sensor, actuator and so on without parts removal. Reading the DATA LIST as the first step of troubleshooting is one method to shorten labor time.

    1. Warm up the engine.
    2. Turn the ignition switch off.
    3. Connect the OBD II scan tool or hand-held tester to the DLC3.
    4. Turn the ignition switch to the ON position.
    5. According to the display on tester, read the "DATA LIST".
      Fig 1: Data List Specification Chart
      G03096167Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. ACTIVE TEST 

    HINT:

    Performing the ACTIVE TEST using the hand-held tester allows the relay, VSV, actuator and so on to operate without parts removal. Performing the ACTIVE TEST as the first step of troubleshooting is one method to shorten labor time.

    It is possible to display the DATA LIST during the ACTIVE TEST.

    1. Warm up the engine.
    2. Turn the ignition switch off.
    3. Connect the hand-held tester to the DLC3.
    4. Turn the ignition switch to the ON position.
    5. According to the display on tester, perform the "ACTIVE TEST".
      Fig 2: Active Test Specification Chart
      G03096168Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    6. HINT:

      The pressure values in ACTIVE TEST and HYDRAULIC TEST are different from each other.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.