Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2005 Scion xB AutomaticFACTORY OEM SERVICE PROCEDURE
Inspection Procedure
- CHECK OPERATION OF STOP LAMP
- Check whether the stop lamps turn on and off normally when the brake pedal is depressed and released.
OK: Stop lamps turn ON when brake pedal is depressed.
- NG: REPAIR OR REPLACE STOP LAMP SWITCH CIRCUIT
- OK: Go to next step.
- READ VALUE USING HAND-HELD TESTER OR OBD II SCAN TOOL (STP SIGNAL AND ST1- VOLTAGE)
- Connect a hand-held tester or OBD II scan tool to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester or scan tool ON.
- On the tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / STOP LIGHT SW.
- Read the value displayed on the tester.
- If using an OBD II scan tool, refer to the instruction manual .
Standard:
STP SIGNAL AND ST1- VOLTAGEBrake Pedal Operations Specified Conditions Depressed STP Signal ON Released STP Signal OFF
- OK: CHECK FOR INTERMITTENT PROBLEMS (See CHECK FOR INTERMITTENT PROBLEMS )
- NG: Go to next step
- INSPECT STOP LAMP SWITCH ASSY
- Check the resistance when the stop lamp switch is ON and OFF.
Standard:
STOP LAMP SWITCH ASSYSwitch Positions Tester Connections Specified Conditions ON (Free) 1 - 2 Below 1 Ω OFF (Pushed in) 1 - 2 10 kΩ or higher
- NG: REPLACE STOP LAMP SWITCH ASSY
- OK: Go to next step.
- Check the resistance when the stop lamp switch is ON and OFF.
- CHECK HARNESS AND CONNECTOR (STOP LAMP SWITCH - ECM)
- Disconnect the S8 stop lamp switch connector.
- Disconnect the E4 ECM connector.
- Check the resistance.
Standard (Check for open):
STOP LAMP SWITCH - ECM (CHECK FOR OPEN)Tester Connections Specified Conditions Stop lamp switch (S8-1) - STP (E4-19) Below 1 Ω Standard (Check for short):
STOP LAMP SWITCH - ECM (CHECK FOR SHORT)Tester Connections Specified Conditions Stop lamp switch (S8-1) or STP (E4-19) - Body ground 10 kΩ or higher
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.