Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2005 Scion xA StandardFACTORY OEM SERVICE PROCEDURE
Inspection Procedure
- CHECK OPERATION OF STOP LAMP
- Check whether the stop lamps turn on and off normally when the brake pedal is depressed and released.
OK : Stop lamps turn ON when brake pedal is depressed.
- NG : REPAIR OR REPLACE STOP LAMP SWITCH CIRCUIT
- OK : GO TO NEXT STEP
- Check whether the stop lamps turn on and off normally when the brake pedal is depressed and released.
- READ VALUE USING HAND-HELD TESTER OR OBD II SCAN TOOL (STP SIGNAL AND ST1- VOLTAGE)
- Connect a hand-held tester or OBD II scan tool to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester or scan tool ON.
- On the tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / STOP LIGHT SW.
- Read the value displayed on the tester.
- If using an OBD II scan tool, refer to the instruction manual.
Standard:
BRAKE PEDAL OPERATIONS SPECIFIED CONDITIONSBrake Pedal Operations Specified Conditions Depressed STP Signal ON Released STP Signal OFF Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- OK : (See CHECK FOR INTERMITTENT PROBLEMS )
- NG : GO TO NEXT STEP
- INSPECT STOP LAMP SWITCH ASSY
- Check the resistance when the stop lamp switch is ON and OFF.
Standard:
STOP LAMP SWITCH ASSY RESISTANCE SPECIFICATIONSSwitch Positions Tester Connections Specified Conditions ON (Free) 1 - 2 Below 1 Ω OFF (Pushed in) 1 - 2 10 kΩ or higher - NG : REPLACE STOP LAMP SWITCH ASSY
- OK : GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (STOP LAMP SWITCH - ECM)
- Disconnect the S6 stop lamp switch connector.
- Disconnect the E5 ECM connector.
- Check the resistance.
Standard (Check for open):
RESISTANCE SPECIFICATIONS FOR OPENTester Connections Specified Conditions Stop lamp switch (S6-1) - STP (E5-19) Below 1 Ω Standard (Check for short):
RESISTANCE SPECIFICATIONS FOR SHORTTester Connections Specified Conditions Stop lamp switch (S6-1) or STP (E5-19) - Body ground 10 kΩ or higher - Reconnect the stop lamp switch connector.
- Reconnect the ECM connector.
- NG : REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK : REPLACE ECM (See REPLACEMENT )
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.