2007 Saturn ION L4-2.2LFACTORY OEM SERVICE PROCEDURE
Catalytic Converter: Service and Repair
Catalytic Converter Replacement (RPO L61)
Removal Procedure
1. If equipped with regular production option (RPO) MN5, remove the heated oxygen sensor (HO2S) connector position assurance (CPA) retainer.
2. Disconnect the HO2S lead from the engine harness electrical connector (4).
3. If equipped with RPO M86, remove the HO2S CPA retainer (4).
4. Disconnect the HO2S lead from the engine harness electrical connector (5).
5. Remove the wheel drive shaft heat shield.
6. Bend the heat shield trough (2) down slightly until the HO2S lead (1) can be removed.
7. Remove the HO2S.
8. Remove the catalytic converter to muffler pipe nuts.
9. Pull the muffler pipe rearward and down until the studs are removed from the catalytic converter.
10. Remove the catalytic converter pipe to exhaust manifold nuts.
11. Remove the catalytic converter.
12. Remove and discard the exhaust gaskets.
13. Clean the flange mating surfaces of any remaining gasket material.
Installation Procedure
1. Install a NEW gasket onto the exhaust manifold studs.
2. Install the catalytic converter.
Notice: Refer to Fastener Notice.
3. Install the catalytic converter pipe to exhaust manifold nuts.
Tighten the nuts to 50 N.m (37 lb ft).
4. Install a NEW gasket onto the muffler pipe studs.
5. Pull the muffler pipe rearward and up until the studs are installed to the catalytic converter.
6. Install the catalytic converter to muffler pipe nuts.
Tighten the nuts to 30 N.m (22 lb ft).
7. If reinstalling the old HO2S, coat the threads with anti-seize compound, Saturn P/N 21485279 or equivalent.
8. Install the HO2S.
Tighten the sensor to 42 N.m (31 lb ft).
9. Route the HO2S lead (1) through the heat shield trough, once done bend the trough (2) until the HO2S lead is secured.
10. Install the wheel drive shaft heat shield.
11. If equipped with RPO M86, connect the HO2S lead to the engine harness electrical connector (5).
12. Install the HO2S CPA retainer (4).
13. If equipped with RPO MN5, connect the HO2S lead to the engine harness electrical connector (4).
14. Install the HO2S CPA retainer.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.