2005 Saturn Vue Base, 2.2 D, AWDFACTORY OEM SERVICE PROCEDURE

Removal Procedure

  1. Disconnect the intake air temperature (IAT) sensor connector.
  2. Loosen the clamp at the air cleaner assembly.
    Fig 1: Identifying Outlet Resonator/Duct Assembly
    GM898897Courtesy of GENERAL MOTORS CORP.
  3. Remove the push-pin attachment from the outlet resonator/duct assembly to support bracket.
  4. Loosen the clamp at the throttle body assembly.
  5. Disconnect the PCV fresh air bent hose at the cam cover.
  6. Remove the outlet resonator/duct assembly.
  7. Disconnect the EI module electrical connector.
  8. Remove the ignition module attachment bolts.
  9. Remove the ignition module housing assembly with the spark plug boots from the spark plugs.
    Fig 2: View of Ignition Module Housing Assembly With Spark Plug Boots
    GM951506Courtesy of GENERAL MOTORS CORP.
  10. IMPORTANT: To avoid getting water and debris into the spark plug holes, used compressed air and a shop rag to blow out each spark plug hole before plus are removed.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.