2002 Saturn SC2 Automatic, MP6FACTORY OEM SERVICE PROCEDURE

Electrical Connections Or Wiring

  1. Intermittents are usually caused by one or more of the following conditions:
    • Poor electrical connections.
    • Terminal tension.
    • Wiring problems.
  2. Carefully inspect the suspected circuit for the following conditions:
    • Poor mating of the connector halves.
    • Terminals backed out or not fully seated in the connector body.
    • Improperly formed or damaged terminals. Test for poor terminal tension.
    • Poor terminal-to-wire connections including terminals crimped over insulation. This requires removing the terminal from the connector body.
    • Corrosion or water intrusion. Pierced or damaged insulation can allow moisture to enter the wiring. The conductor can corrode inside the insulation, with little visible evidence. Look for swollen and stiff sections of wire in the suspect circuits.
    • Wires that are broken inside the insulation.
    • Pinched, cut, or rubbed through wiring in the harness.
    • Wiring that is in contact with hot exhaust components.
  3. Repair the condition as necessary.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.