2002 Saturn SC2 Automatic, MP6FACTORY OEM SERVICE PROCEDURE

Removal & Installation: Generator: Removal

  1. Disconnect battery negative cable.
  2. Remove accessory belt.
  3. Raise and support vehicle on a hoist.
  4. Remove right wheel
  5. Remove right wheel well splash shield.
  6. Disconnect the field wires from generator.
  7. NOTE: Failure to hold stud when loosening the lock nut may crack the plastic insulator and cause generator to fail.
  8. Disconnect fusible link wire using the Generator Output Stud Wrench (SA9401C) to hold the generator output (B+) stud from rotating.
  9. Remove lower and upper generator attachment bolts.
  10. Remove generator through the wheel well opening behind the strut.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.