Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2002 Saturn L100 L4-2.2L VIN FFACTORY OEM SERVICE PROCEDURE
Spark Plug: Service and Repair
REMOVAL

1. Ignition Off.
2. Disconnect EI module harness connector.
3. Remove ignition coil housing attachment bolts and remove ignition coil housing.
IMPORTANT: Make sure water and debris are blown out of spark plug holes before removing spark plugs.
4. Remove spark plugs using a 5/8 in. spark plug socket.
INSTALLATION
Spark Plug Gap: 1.1 mm (0.45 in.)
NOTE: DO NOT coat spark plug threads with anti-seize compound. If anti-seize compound is used and spark plugs are over-torqued, damage to the cylinder head threads may result.

1. Install spark plugs.
Torque:
Spark Plugs: 20 N.m (15 ft-lbs)
2. Apply dielectric compound to spark plug boots and make sure no corrosion is present.
3. Install ignition coil housing to cam cover and attachment bolts.
Torque:
Ignition Coil Housing Bolts: 10 N.m (89 in-lbs)
4. Connect EI module harness connector. Push in until a click is heard and pull back to confirm a positive engagement.
1. Ignition Off.
2. Disconnect EI module harness connector.
3. Remove ignition coil housing attachment bolts and remove ignition coil housing.
IMPORTANT: Make sure water and debris are blown out of spark plug holes before removing spark plugs.
4. Remove spark plugs using a 5/8 in. spark plug socket.
INSTALLATION
Spark Plug Gap: 1.1 mm (0.45 in.)
NOTE: DO NOT coat spark plug threads with anti-seize compound. If anti-seize compound is used and spark plugs are over-torqued, damage to the cylinder head threads may result.
1. Install spark plugs.
Torque:
Spark Plugs: 20 N.m (15 ft-lbs)
2. Apply dielectric compound to spark plug boots and make sure no corrosion is present.
3. Install ignition coil housing to cam cover and attachment bolts.
Torque:
Ignition Coil Housing Bolts: 10 N.m (89 in-lbs)
4. Connect EI module harness connector. Push in until a click is heard and pull back to confirm a positive engagement.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.