Seed & Key Method

2000 Saturn SL2 Automatic, MP6SECTION Seed & Key Method
NOTE: Seed & key method takes 10 minutes to perform.
  1. Check BCM and PCM for existing DTCs. If DTCs exist, repair as necessary and go to next step. If no DTCs exist, go to next step.
  2. NOTE: If ignition switch is turned to OFF position before SECURITY indicator light changes state, relearn procedure must be restarted.
  3. Install scan tool. Turn ignition switch to RUN position. Using scan tool in PROGRAMMING SYSTEM mode, select PASSLOCK RELEARN procedure. Wait 10 minutes. When SECURITY indicator light changes from a flashing or on state to an off state, turn ignition switch to OFF position. Vehicle should start on next ignition cycle.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.