2000 Saturn SC2 Automatic, MP6FACTORY OEM SERVICE PROCEDURE

Blower Relay

Remove blower motor relay from underhood fuse block. Using a fused jumper wire, connect battery voltage to terminal F1 of relay and connect ground to terminal A1. See WIRING DIAGRAMSΒ  . Using DVOM, check continuity between terminals D1 and F2. Continuity should exist.