2000 Saab 9-3 Base, 2D Convertible, StandardFACTORY OEM SERVICE PROCEDURE

Output Test

NOTE: Ensure B+ connection at generator is tight and insulating sleeve is not pinched between nut and washer. See Figure . Generator output may be low if connection is loose.
  1. Ensure connections at battery, generator, and starter are clean and tight. Ensure generator, engine, and body are properly grounded. Ensure generator drive belt is tight and in good condition.
  2. Connect ammeter following manufacturer's instructions. Connect voltmeter leads to battery terminals. Start engine and run at 3000 RPM. Adjust carbon pile on tester to obtain maximum generator output. DO NOT allow voltage to drop to less than 12.6 volts.
  3. Output should equal generator rating (stamped on generator) minus 16-20 amps. If output is more than 16-20 amps below generator rating, replace regulator and retest. If output is still low, repair or replace generator.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.