1985 Renault Fuego StandardFACTORY OEM SERVICE PROCEDURE

Airflow Meter Potentiometer

Turn ignition switch off. Unplug electrical connector from airflow meter. Using an ohmmeter, note first reading between terminals 7 and 8. Record a second reading between terminals 6 and 9. Divide the first reading by the second reading. The result should equal .48-.52 ohms. Replace airflow meter if results are not as specified.