2000 Porsche Boxster (986) F6-2.7LFACTORY OEM SERVICE PROCEDURE

DME Setpoints



DME Setpoints

Boundary conditions
- Ambient temperature approx. 20 °C
- Engine temperature 90 - 105 °C
- All loads switched off
- Engine idling


Part 1:

Factory service manual diagram



Part 2:

Factory service manual diagram



Part 3:

Factory service manual diagram





NOTE: The stated values are the result of measurements of vehicles with different mileages and in perfect condition. Different values can result from diagnosis in the workshop because of mileage and environmental influence. For DME diagnosis, it is important to look at several values simultaneously and in a collective group during troubleshooting.

Example:
An important collective group is formed by the following values:


Factory service manual diagram





General test point

No communication with the Porsche System Tester 2.

Test
1. Test voltage supply at the 16-pole data link connector (on the left in the driver's footwell).

NOTE: The alarm system must be deactivated.


Factory service manual diagram



Factory service manual diagram





Connector assignment:
Pin 4 Ground
Pin 5 Electronics ground
Pin 16 Supply voltage (terminal 30) via fuse B 1
Pin 7 Diagnosis K-line via alarm control module

2. Ignition "ON"
Connect voltmeter to pin 16 and pin 4
Display: approx. 12 Volt

Connect voltmeter to pin 16 and pin 5
Display: approx. 12 Volt


Factory service manual diagram





A - DME control module
B - Alarm control module
C - Data link connector
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.