1986 Porsche 944 Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Fuel Evaporation System: Operation

Expanded fuel, caused by high ambient temperatures, is collected in the expansion tank. This fuel is returned to main tank by venting action as fuel is used from main tank.

Fuel vapor produced in main tank passes through a vent line to the charcoal canister where it is stored in activated charcoal. A second vent line, with control valve, connects canister to air cleaner and intake system.

When engine is running, intake vacuum draws fresh air through charcoal canister. This fresh air mixes with fuel vapor and is drawn into intake system where it enters combustion chamber to be burned.

Fig 1: Fuel Evaporation System (928S)
G38561

The thermo valve, switching valve and control valve are connected in series to control amount of vapor purge.

The thermo valve opens at coolant temperatures above 136°F (58°C) to apply vacuum to the switching valve. The switching valve receives vacuum when coolant temperature is above 136°F (58°C) and when throttle valve angle is at least 1°. The control valve receives vacuum from a separate vacuum line that is taken from a port below the throttle valve. This allows control valve to vary amount of purging dependent upon throttle angle. These 3 devices, working in conjunction with each other, ensure purging occurs only when coolant temperature exceeds 136°F (58°C) and throttle valve angle is at least 1°.

Fig 2: Fuel Evaporation System (944 & 944 Turbo)
G37939
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.