1985 Porsche 944 AutomaticFACTORY OEM SERVICE PROCEDURE

Air Temperature Sensor

Disconnect airflow sensor plug. Connect ohmmeter to airflow sensor terminals 6 and 22. Compare ohmmeter readings to specifications chart.

AIR TEMPERATURE SENSOR I SPECIFICATIONS

Temperature Ohms (+/- 10%)
32°F (0°C) 5000-6200
68°F (20°C) 2200-2800
86°F (30°C) 150-1900