2004 Pontiac Aztek FWD V6-3.4L VIN EFACTORY OEM SERVICE PROCEDURE

Blower Motor Control Processor

BLOWER MOTOR CONTROL PROCESSOR REPLACEMENT

REMOVAL PROCEDURE
1. Remove the right side I/P insulator.

Factory service manual diagram



2. Disconnect the blower motor electrical connector.
3. Remove the blower motor mounting screws.
4. Remove the blower motor from the HVAC module assembly.

Factory service manual diagram



5. Disconnect the electrical connector from the blower motor control processor assembly.
6. Remove the forward blower control processor mounting screws.
7. Remove the rearward blower control processor mounting screw.

Factory service manual diagram



8. Remove the blower control processor assembly from the HVAC module assembly.

INSTALLATION PROCEDURE

Factory service manual diagram



1. Install the blower motor control processor assembly to the HVAC module assembly.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the rearward mounting screw.

Tighten
Tighten the screw to 1.8 N.m (16 lb in).

3. Install the forward mounting screws.

Tighten
Tighten the screws to 1.8 N.m (16 lb in).

Factory service manual diagram



4. Connect the electrical connector to the blower control processor assembly.
5. Install the blower motor to the HVAC module assembly.
6. Install the blower motor mounting screws.

Tighten
Tighten the screws to 1.8 N.m (16 lb ft).

Factory service manual diagram



7. Connect the blower motor electrical connector.
8. Install the right side I/P insulator.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.