Scan Tool Data Definitions
Battery Voltage: The scan tool displays 0-17.5 volts. The scan tool displays the voltage as received by the BCM.
GEN F-Terminal Signal: The scan tool displays 0-100%. The scan tool displays a steady percentage value until the engine is running, then the percentage value varies depending on electrical loads
GEN L-Terminal Signal Command: The scan tool displays On/Off. The scan tool displays Off until the engine is running, then the PCM supplies about 5 volts to the L - Terminal of the generator and the scan tool displays On.
Ignition 1 Signal: The scan tool displays 0-20 volts. The scan tool displays the voltage as received on the Ignition 1 circuit to the PCM.
TR Sw: The scan tool displays Park/Reverse/Neutral/Drive4/Drive3/Drive2/Drive1. The scan tool displays the current physical gear of the Trans Range switch.
Volt Lamp: The scan tool displays On/Off. The scan tool displays On when the IPC has been commanded by another module to command the Volt Lamp On.
GEN F-Terminal Signal: The scan tool displays 0-100%. The scan tool displays a steady percentage value until the engine is running, then the percentage value varies depending on electrical loads
GEN L-Terminal Signal Command: The scan tool displays On/Off. The scan tool displays Off until the engine is running, then the PCM supplies about 5 volts to the L - Terminal of the generator and the scan tool displays On.
Ignition 1 Signal: The scan tool displays 0-20 volts. The scan tool displays the voltage as received on the Ignition 1 circuit to the PCM.
TR Sw: The scan tool displays Park/Reverse/Neutral/Drive4/Drive3/Drive2/Drive1. The scan tool displays the current physical gear of the Trans Range switch.
Volt Lamp: The scan tool displays On/Off. The scan tool displays On when the IPC has been commanded by another module to command the Volt Lamp On.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.