Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2002 Pontiac Aztek V6-3.4L VIN EFACTORY OEM SERVICE PROCEDURE
Control Module HVAC: Service and Repair
BLOWER MOTOR CONTROL PROCESSOR REPLACEMENT
REMOVAL PROCEDURE

1. Remove the right side instrument panel insulator.
2. Disconnect the blower motor electrical connector.
3. Remove the blower motor mounting screws.
4. Remove the blower motor from the HVAC module assembly.

5. Disconnect the electrical connector from the blower motor control processor assembly.
IMPORTANT: Only loosen both of the forward blower control processor mounting screws. The forward blower control processor mounting holes are slotted.

6. Loosen the forward blower control processor mounting screws.
7. Remove the rearward blower control processor mounting screw.
8. Remove the blower control processor assembly from the HVAC module assembly.
INSTALLATION PROCEDURE

1. Install the blower motor control processor assembly to the HVAC module assembly.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the rearward blower control processor mounting screw.
Tighten
Tighten all of the screws to 1.8 N.m (16 lb in).

3. Connect the electrical connector to the blower control processor assembly.
4. Install the blower motor to the HVAC module assembly.
5. Install the blower motor mounting screws.
Tighten
Tighten the screws to 1.8 N.m (16 lb ft).

6. Connect the blower motor electrical connector.
7. Install the right side instrument panel insulator.
REMOVAL PROCEDURE
1. Remove the right side instrument panel insulator.
2. Disconnect the blower motor electrical connector.
3. Remove the blower motor mounting screws.
4. Remove the blower motor from the HVAC module assembly.
5. Disconnect the electrical connector from the blower motor control processor assembly.
IMPORTANT: Only loosen both of the forward blower control processor mounting screws. The forward blower control processor mounting holes are slotted.
6. Loosen the forward blower control processor mounting screws.
7. Remove the rearward blower control processor mounting screw.
8. Remove the blower control processor assembly from the HVAC module assembly.
INSTALLATION PROCEDURE
1. Install the blower motor control processor assembly to the HVAC module assembly.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the rearward blower control processor mounting screw.
Tighten
Tighten all of the screws to 1.8 N.m (16 lb in).
3. Connect the electrical connector to the blower control processor assembly.
4. Install the blower motor to the HVAC module assembly.
5. Install the blower motor mounting screws.
Tighten
Tighten the screws to 1.8 N.m (16 lb ft).
6. Connect the blower motor electrical connector.
7. Install the right side instrument panel insulator.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.