2000 Pontiac Firefly (CANADA) L3-1.0LFACTORY OEM SERVICE PROCEDURE

ECT Sensor Replacement

Factory service manual diagram




REMOVAL PROCEDURE

NOTE: Use care when handling the coolant sensor. Damage to the coolant sensor will affect the operation of the fuel control system.

1. Drain the engine coolant system. Refer to Draining and Filling Cooling System the Engine Cooling.
2. Disconnect the ECT sensor electrical connector.
3. Remove the ECT sensor from the thermostat housing.

INSTALLATION PROCEDURE

NOTE: Refer to Component Tightening Notice in Service Precautions.

1. Install the ECT sensor to the thermostat housing.

Tighten
Tighten the ECT sensor to 10 to 20 N.m (7.5 to 14 lb ft).

2. Connect the ECT sensor electrical connector.
3. Fill the engine coolant system to the proper level. Refer Draining and Filling Cooling System to Engine Cooling.
Factory Service Tools