1996 Pontiac Firebird Formula, 2D Convertible, StandardFACTORY OEM SERVICE PROCEDURE

Right Front Window Does Not Operate

  1. Turn ignition switch to RUN position. Using a test light, backprobe between Dark Blue wire and Brown wire terminals at right window motor connector. While observing test light, press right window switch to up and down positions. If test light is off, go to next step. If test light is on, check for poor connection at right window motor. If connection is okay, replace motor.
  2. Backprobe between Dark Blue wire and Brown wire terminals at right window switch connector. While observing test light, press right window switch to up and down positions. If test light is off, go to next step. If test light is on, repair open in Dark Blue wire or Brown wire between right window switch and motor.
  3. Backprobe between Light Blue wire and Tan wire terminals at right window switch connector. While observing test light, press right window switch at master switch to up and down positions. If test light is off, go to next step. If test light is on, check for poor connection at right window switch. If connection is okay, replace right window switch.
  4. Backprobe between Light Blue wire and Tan wire terminals at master switch connector. While observing test light, press right window switch at master switch to up and down positions. If test light is on, check for poor connection at master switch. If connection is okay, repair open in Light Blue wire or Tan wire between master switch and right window switch. If test light is off, check for poor connection at master switch. If connection is okay, replace master switch.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.