1993 Pontiac Firebird Formula, AutomaticFACTORY OEM SERVICE PROCEDURE

Code 71 - A/C Temperature (Circuit Open Or Shorted): Notes

The A/C system uses an A/C evaporator temperature sensor mounted in the A/C evaporator core to monitor A/C temperature for use by the ECM. The ECM uses this information to cycle the A/C compressor clutch so optimum cooling is attained. This will also prevent evaporator core freezing. The ECM will disable the A/C compressor clutch when A/C evaporator temperature is less than 36Β°F (2Β°C). A Code 71 will set under improper operating conditions; however, SERVICE ENGINE SOON light will not illuminate.

NOTE: Test numbers refer to numbers on diagnostic chart.
  1. Code 71 will set if A/C is requested and the ECM detects an open, short to ground or short to voltage in the evaporator temperature sensor circuit. All conditions must be met for 3 seconds for code to be set.
  2. With A/C evaporator sensor disconnected, normal voltage on circuit is near 5 volts. If a short to voltage is suspected, reconnect sensor harness and backprobe terminal "B" of sensor harness using a DVOM. If 5 volts or more is indicated, circuit is shorted to voltage.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.