1986 Pontiac 6000 STEFACTORY OEM SERVICE PROCEDURE

Pump Runs Continuously

  1. Check all attaching hoses for leaks. Repair as required. With ignition off, remove inlet hose from pump and connect hand vacuum pump to inlet. Turn ignition on. With 10 in. Hg applied, if pump continues to run, replace controller.
  2. If pump shuts off when vacuum reaches 10-15 in. Hg, drop vacuum back to less than 10 in. Hg. Pump should run until vacuum reaches 10 in. Hg, then shut off after 5-10 seconds. If so, pump is okay.