1995 Plymouth Grand Voyager BaseFACTORY OEM SERVICE PROCEDURE

Engine Controls - Basic Testing - 3.3L CNG: Introduction

NOTE: For diagnostic procedures on systems used in common with gasoline powered vehicles, proceed to BASIC TESTING - 3.3L GASOLINE article in the ENGINE PERFORMANCE section.

The following diagnostic steps can help prevent overlooking a simple problem. Also use this article to begin diagnosis for a no-start condition. The first step in diagnosing any driveability problem is verifying the customer's complaint with a test drive under conditions in which the problem reportedly occurs.

Before entering self-diagnostics, perform a careful and complete visual inspection. Most driveability and no-start problems are not related to computerized engine control systems, but are simple mechanical, electrical, fuel or vacuum related faults. Most engine control problems are the result of mechanical breakdowns, poor electrical connections, or damaged or misrouted vacuum hoses. Before condemning the computerized engine control system, perform each test listed in this article.

NOTE: All voltage tests should be performed using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance unless stated otherwise in testing procedures.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.