1981 Plymouth Champ LS, Automatic TransFACTORY OEM SERVICE PROCEDURE

Tool C-38***29A Method (Negative Rectifiers)

  1. Remove alternator brushes and through bolts. Separate rectifier end shield and stator from drive end shield, pulley and rotor.
  2. Connect test lead clip to rectifier end housing. Touch metal strap of each negative rectifier with test probe. Test specifications and results will be approximately the same as for positive rectifiers, except meter will read on opposite side of scale.
NOTE: If negative rectifier shows shorted, remove stator from rectifier end shield and retest. Stator winding could be grounded to stator laminations or end shield. This would indicate a shorted negative rectifier.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.