1976 Plymouth Arrow Base, Automatic TransFACTORY OEM SERVICE PROCEDURE

Current Output

  1. With test connections made as for "Charging Circuit Resistance", move negative lead of voltmeter to a good ground, then move the positive lead of voltmeter to "BAT" terminal of alternator. Start engine and operate at idle.
    CAUTION: To avoid damage, reduce engine speed to idle immediately after starting.
  2. Adjust engine speed and carbon pile until a speed of 900 RPM (100 amp.) or 1250 RPM (all others) and a voltmeter reading of 13 volts (100 amp.) or 15 volts (all others) is obtained.
    CAUTION: Increases in engine speed should not be large enough to allow voltage to exceed 16 volts.

    Observe ammeter, current output should be within specifications. If output is slightly less (5-7 amps.) than specified, it may be an indication of possible "open" rectifier or other alternator internal problem. On models equipped with Field-Loads relay, check relay operation before diagnosing alternator problems. See Chrysler Corp. Regulators in this section.Β  If output is considerably lower, it may be an indication of a possible "shorted" rectifier or other internal problem.

Fig 1: CURRENT OUTPUT TEST (DART & VALIANT)
G09321353Courtesy of CHRYSLER GROUP, LLC
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.