1998 Oldsmobile Cutlass BaseFACTORY OEM SERVICE PROCEDURE

DTC U2002: Transmitted SPI Data Input Low: Description

DTC U2002 indicates that BFC has detected a short to ground on SPI data line from instrument cluster to BFC. DTC U2002 will set when Ignition 0 is active, and when all 3 data bytes received from instrument cluster are zero for 64 transmission cycles. DTC U2002 can be cleared using scan tool, or history DTC will disappear after 100 ignition cycles if fault conditions do not reoccur.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.