2016 Nissan-Datsun Sentra SLFACTORY OEM SERVICE PROCEDURE

Encoder Circuit Check

  1. CHECK ENCODER OPERATION

    1. Connect front power window motor LH.
    2. Turn ignition switch ON.
    3. Check signal between main power window and door lock/unlock switch connector D5 and ground with oscilloscope.
      Terminals Signal
      (Reference value)
      (+) (-)
      Main power window and door lock/unlock switch
      connector
      Terminal
      D5 4 Ground Refer to following signal
      5
      Fig 1: Checking Signal Between Power Window Main Switch Harness Connector And Ground Using Oscilloscope
      G06934392Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    GO TO STEP 2  .

  2. CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY

    1. Turn ignition switch ON.
    2. Check voltage between front power window motor LH connector D8 and ground.
      Terminal Voltage
      (Approx.)
      (+) (-)
      Front power window motor LH connector Terminal
      D8 2 Ground Battery voltage

    Is the inspection result normal?

    YES 

    GO TO STEP 4  .

    NO 

    GO TO STEP 3. 

  3. CHECK HARNESS CONTINUITY 1

    1. Turn ignition switch OFF.
    2. Disconnect main power window and door lock/unlock switch and front power window motor LH.
    3. Check continuity between main power window and door lock/unlock switch connector D5 and front power window motor connector D8.
      Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity
      D5 14 D8 2 Yes
    4. Check continuity between main power window and door lock/unlock switch connector D5 and ground.
      Main power window and door lock/unlock switch connector Terminal Ground Continuity
      D5 14 No

    Is the inspection result normal?

    YES 

    Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .

    NO 

    Repair or replace harness or connectors.

  4. CHECK GROUND CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect front power window motor LH.
    3. Check continuity between front power window motor LH connector D8 and ground.
      Front power window motor LH connector Terminal Ground Continuity
      D8 6 Yes

    Is the inspection result normal?

    YES 

    GO TO STEP 6  .

    NO 

    GO TO STEP 5  .

  5. CHECK HARNESS CONTINUITY 2

    1. Disconnect main power window and door lock/unlock switch.
    2. Check continuity between main power window and door lock/unlock switch connector D5 and front power window motor LH connector D8.
      Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity
      D5 12 D8 6 Yes

    Is the inspection result normal?

    YES 

    Check main power window and door lock/unlock switch. Refer to COMPONENT INSPECTION .

    NO 

    Repair or replace the harness or connectors.

  6. CHECK HARNESS CONTINUITY 3

    1. Disconnect main power window and door lock/unlock switch.
    2. Check continuity between main power window D5 and door lock/unlock switch connector and front power window motor LH connector D8.
      Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity
      D5 4 D8 5 Yes
      5 4
    3. Check continuity between main power window and door lock/unlock switch connector D5 and ground.
      Main power window and door lock/unlock switch connector Terminal Ground Continuity
      D5 4 No
      5

    Is the inspection result normal?

    YES 

    Replace front power window motor LH. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .

    NO 

    Repair or replace harness or connectors.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote