2012 Nissan-Datsun Sentra SE-RFACTORY OEM SERVICE PROCEDURE

Control Valve: Removal

  1. Remove drain plug from oil pan and then drain the CVT fluid.
  2. Remove drain plug gasket.
  3. Disconnect battery cable from negative terminal. Refer to , "REMOVAL AND INSTALLATION (MR20DE BATTERY) " (MR20DE) or , "REMOVAL AND INSTALLATION (QR25DE BATTERY) " (QR25DE).
  4. Disconnect the CVT unit connector. Refer to "REMOVAL AND INSTALLATION PROCEDURE FOR CVT UNIT CONNECTORΒ ".
  5. Remove the snap ring (1) from the CVT unit connector (A).
    Fig 1: Identifying CVT Unit Connector And Snap Ring
    G05866293Courtesy of NISSAN NORTH AMERICA, INC.
  6. Press the CVT unit connector (A) into the transaxle case.
    CAUTION: Never damage the CVT unit connector.