2012 Nissan-Datsun Quest SLFACTORY OEM SERVICE PROCEDURE

Diagnosis Procedure

  1. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
    1. Disconnect refrigerant pressure sensor harness connector.
    2. Turn ignition switch ON.
    3. Check the voltage between refrigerant pressure sensor harness connector and ground.
      Refrigerant pressure sensor Ground Voltage (V)
      Connector Terminal
      E300 1 Ground Approx. 5

      Is the inspection result normal? 

      YES: GO TO  3.

      NO: GO TO 2.

  2. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
      Refrigerant pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      E300 1 F8 96 Existed

      Is the inspection result normal? 

      YES: Perform the trouble diagnosis for power supply circuit.

      NO: Repair or replace error-detected parts.

  3. CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
      Refrigerant pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      E300 3 F8 64 Existed
    4. Also check harness for short to ground and short to power.

      Is the inspection result normal? 

      YES: GO TO 4.

      NO: Repair or replace error-detected parts.

  4. CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
      Refrigerant pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      E300 2 F8 63 Existed
    2. Also check harness for short to ground and short to power.

      Is the inspection result normal? 

      YES: GO TO 5.

      NO: Repair or replace error-detected parts.

  5. CHECK INTERMITTENT INCIDENT

    Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".

    Is the inspection result normal? 

    YES: Replace refrigerant pressure sensor. Refer to "EXPLODED VIEW ".

    NO: Repair or replace error-detected parts.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.