Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
TERMINAL VOLTAGE REFERENCE CHARTEVAP control system pressure sensor Ground Voltage Connector Terminal B21 3 Ground Approx. 5 V Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
TERMINAL CONTINUITY REFERENCE CHARTEVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B21 3 F8 76 Existed Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B4, M79
- Harness connectors M77, E105
- Harness connectors E8, F1
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
TERMINAL REFERENCE CHARTECM Sensor Connector Terminal Name Connector Terminal F8 74 Refrigerant pressure sensor E49 3 75 CKP sensor (POS) F20 1 76 EVAP control system pressure sensor B21 3 77 Battery current sensor F51 1 E16 102 APP sensor E110 5 Is the inspection result normal?
YES: GO TO 7.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to "DIAGNOSIS PROCEDURE ".)
Is the inspection result normal?
YES: GO TO 8.
NO: Replace malfunctioning component.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 9.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
- Replace accelerator pedal assembly
- Perform "SPECIAL REPAIR REQUIREMENT ".
INSPECTION END
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINAL CONTINUITY REFERENCE CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B21 1 F8 51 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 12.
NO: GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B4, M79
- Harness connectors M77, E105
- Harness connectors E8, F1
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINAL CONTINUITY REFERENCE CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B21 2 F8 42 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 14.
NO: GO TO 13.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B4, M79
- Harness connectors M77, E105
- Harness connectors E8, F1
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK RUBBER TUBE
- Disconnect rubber tube connected to EVAP canister vent control valve.
- Check the rubber tube for clogging.
Is the inspection result normal?
YES: GO TO 15.
NO: Clean the rubber tube using an air blower, repair or replace rubber tube.
- CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 16.
NO: Replace EVAP canister vent control valve.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 17.
NO: Replace EVAP control system pressure sensor.
- CHECK IF EVAP CANISTER IS SATURATED WITH WATER
- Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
- Check if water will drain from the EVAP canister.
Does water drain from EVAP canister?
YES: GO TO 18.
NO: GO TO 20.
- CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor attached.
The weight should be less than 1.9 kg (4.2 lb).
Is the inspection result normal?
YES: GO TO 20.
NO: GO TO 19.
- DETECT MALFUNCTIONING PART
Check the following.
- EVAP canister for damage
- EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
Repair hose or replace EVAP canister.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.