Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Diagnosis Procedure
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
- Check the voltage between ECM harness connector and ground.
TERMINAL VOLTAGE REFERENCE CHARTECM Ground Voltage Connector Terminal E16 105 Ground Battery voltage Is the inspection result normal?
YES: GO TO 2.
NO: Go to "DIAGNOSIS PROCEDURE ".
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect Condenser harness connector.
- Turn ignition switch ON.
- Check the voltage between condenser harness connector and ground.
TERMINAL VOLTAGE REFERENCE CHARTCondenser Ground Voltage Connector Terminal F13 1 Ground Battery voltage Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 3.
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector E43.
- Check the continuity between IPDM E/R harness connector and condenser harness connector.TERMINAL CONTINUITY REFERENCE CHART
IPDM E/R Condenser Continuity Connector Terminal Connector Terminal E14 44 F26 1 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: Go to "DIAGNOSIS PROCEDURE ".
NO: GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E8, F1
- IPDM E/R harness connector E43
- Harness for open or short between IPDM E/R and condenser
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between Condenser harness connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Condenser Ground Continuity Connector Terminal E13 2 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK CONDENSER
Refer to "COMPONENT INSPECTION (CONDENSER) ".
Is the inspection result normal?
YES: GO TO 7.
NO: Replace condenser.
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-V
- Reconnect all harness connectors disconnected.
- Disconnect ignition coil harness connector.
- Turn ignition switch ON.
- Check the voltage between ignition coil harness connector and ground.
TERMINAL VOLTAGE REFERENCE CHARTIgnition coil Ground Voltage Cylinder Connector Terminal 1 F33 3 Ground Battery voltage 2 F34 3 3 F35 3 4 F36 3 Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between ignition coil harness connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Ignition coil Ground Continuity Cylinder Connector Terminal 1 F33 2 Ground Existed 2 F34 2 3 F35 2 4 F36 2 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and ignition coil harness connector.TERMINAL CONTINUITY REFERENCE CHART
Ignition coil ECM Continuity Cylinder Connector Terminal Connector Terminal 1 F33 1 F7 17 Existed 2 F34 1 18 3 F35 1 22 4 F36 1 21 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 10.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL WITH POWER TRANSISTOR
Refer to "COMPONENT INSPECTION (IGNITION COIL WITH POWER TRANSISTOR) ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace malfunctioning ignition coil with power transistor.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.