Diagnostic Procedure
- CHECK EXHAUST SYSTEM
- Start engine and run it at idle.
- Check exhaust pipes and muffler for leaks.
OK or NG
- OK: GO TO 2.
- NG: Repair or replace exhaust system.
- CHECK EGR VOLUME CONTROL VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect EGR volume control valve harness connector.
- Turn ignition switch ON.
- Check voltage between EGR volume control valve terminals 2, 5 and ground with CONSULT-II or tester.
Voltage: Battery voltage
OK or NG
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E22, F35
- IPDM E/R harness connector E122
- Harness for open or short between EGR volume control valve and IPDM E/R
- Repair harness or connectors.
- CHECK EGR VOLUME CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminals and EGR volume control valve terminals as follows. Refer to
WIRING DIAGRAM - EGRC1 .ECM AND EGR VOLUME CONTROL VALVE CONTINUITY
ECM terminal EGR volume control valve 17 6 18 3 19 4 20 1 Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 5.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EGR PASSAGE
Check EGR passage for clogging and cracks.
OK or NG
- OK: GO TO 6.
- NG: Repair or replace EGR passage.
- CHECK EGR VOLUME CONTROL VALVE
Refer to COMPONENT INSPECTION .
OK or NG
- OK: GO TO 7.
- NG: Replace EGR volume control valve.
- CHECK EGR TEMPERATURE SENSOR AND CIRCUIT
Perform DTC Confirmation Procedure for DTC P 0405, P0406. Refer to DTC CONFIRMATION PROCEDURE .
OK or NG
- OK: GO TO 8.
- NG: Repair or replace malfunctioning part.
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- INSPECTION END
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.