Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Trunk Opener Request Switch Check
- CHECK TRUNK OPENER REQUEST SWITCHÂ
With CONSULT-IIIÂ
Check trunk opener request switch ("BD/TR REQ SW") in "DATA MONITOR" mode.
MONITOR ITEM REFERENCE CHARTMonitor item Condition BD/TR REQ SW Trunk opener request switch is pressed: ON Trunk opener request switch is released: OFF Without CONSULT-IIIÂ
- Turn ignition switch OFF.
- Check voltage between Intelligent Key Unit connector M52 terminal 29 and ground.
INTELLIGENT KEY UNIT CONNECTOR M52 TERMINAL 29 AND GROUNDConnector Terminals Condition Voltage (V) (Approx.) (+) (-) M52 29 Ground Trunk opener request switch is pressed 0 Trunk opener request switch is released 5 Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NGÂ
OK: Trunk opener request switch is OK.
NG: GO TO 2.
- CHECK TRUNK OPENER REQUEST SWITCH OPERATIONÂ
- Turn ignition switch OFF.
- Disconnect trunk opener request switch connector.
- Check continuity between trunk opener request switch terminals 1 and 2.
TRUNK OPENER REQUEST SWITCH TERMINALS 1 AND 2Component Terminals Condition Continuity Trunk opener request switch 1 2 Trunk opener request switch is pressed Yes Trunk opener request switch is released No Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NGÂ
OK: GO TO 3.
NG: Replace trunk opener request switch.
- CHECK TRUNK OPENER REQUEST SWITCH GROUND CIRCUITÂ
Check continuity between trunk opener request switch harness connector T6 terminal 2 and ground.
2 - Ground: Continuity should exist.Â
Fig 3: Checking Continuity Between Trunk Opener Request Switch Harness Connector T6 Terminal 2 And GroundCourtesy of NISSAN MOTOR CO., U.S.A.
OK or NGÂ
OK: GO TO 4.
NG: Repair or replace trunk opener request switch ground circuit.
- CHECK TRUNK OPENER REQUEST SWITCH CIRCUITÂ
- Disconnect Intelligent Key unit connector.
- Check continuity between Intelligent Key Unit harness connector M52 terminals 29 and trunk opener request switch harness connector T6 terminal 1.
29 - 1: Continuity should exist.Â
- Check continuity between Intelligent Key Unit harness connector M52 terminal 29 and ground.
29 - Ground: Continuity should not exist.Â
Fig 4: Checking Continuity Between Intelligent Key Unit Harness Connector M52 Terminal 29 And GroundCourtesy of NISSAN MOTOR CO., U.S.A.
OK or NGÂ
OK: GO TO 5.
NG: Repair or replace harness between Intelligent Key Unit and trunk opener request switch.
- CHECK TRUNK OPENER REQUEST SWITCH SIGNALÂ
- Connect Intelligent Key Unit connector.
- Check voltage between trunk opener request switch harness connector T6 terminal 1 and ground.
1 - Ground: Battery voltageÂ
Fig 5: Checking Voltage Between Trunk Opener Request Switch Harness Connector T6 Terminal 1 And GroundCourtesy of NISSAN MOTOR CO., U.S.A.
OK or NGÂ
OK: Check condition of harness and connector.
NG: Replace Intelligent Key Unit. Refer to "REMOVAL AND INSTALLATION OF INTELLIGENT KEY UNITÂ ".
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.