2004 Nissan-Datsun Sentra SE-RFACTORY OEM SERVICE PROCEDURE

IPDM E/R Power/Ground Circuit Inspection

WARNING: This page is about a different car, the 2004 Nissan Titan. However, it is still accessible from the selected car via links, so may be relevant.
  1. FUSE AND FUSIBLE LINK INSPECTION 
    • Check that the following fusible links or IPDM E/R fuses are not blown.
    FUSIBLE LINKS OR IPDM E/R FUSES

    Terminal No. Signal name Fuse, fusible link No.
    1, 2, 22 Battery power a, c, d, e, l

    OK or NG? 

    1. OK: GO TO 2.
    2. NG: Replace fuse or fusible link.
  2. POWER CIRCUIT INSPECTION 
    1. Disconnect IPDM E/R harness connector E118.
    2. Check voltage between IPDM E/R harness connector E118 terminals 1 (B/Y), 2 (R) and ground.

      Battery voltage should exist 

    OK or NG 

    1. OK: GO TO 3.
    2. NG: Replace IPDM E/R power circuit harness.
    Fig 1: Checking Voltage Between IPDM E/R Harness Connector E118 Terminals 1 (B/Y), 2 (R) And Ground
    G03513583Courtesy of NISSAN MOTOR CO., U.S.A.
  3. GROUND CIRCUIT INSPECTION 
    1. Disconnect IPDM E/R harness connectors E122 and E124.
    2. Check continuity between IPDM E/R harness connector E122 terminal 38 (B), and E124 terminal 59 (B) and ground.

      Continuity should exist 

    OK or NG 

    1. OK: Inspection End.
    2. NG: Replace ground circuit harness of IPDM E/R.
    Fig 2: Checking Continuity Between IPDM E/R Harness Connector E122 Terminal 38 (B), And E124 Terminal 59 (B) And Ground
    G03513584Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.