2004 Nissan-Datsun Sentra SE-RFACTORY OEM SERVICE PROCEDURE

Diagnostic Procedure

  1. CHECK OVERALL FUNCTION-I 

    With CONSULT-II 

    1. Turn ignition switch ON.
    2. Select "BRAKE SW1" in "DATA MONITOR" mode with CONSULT-II.
    3. Fig 1: Displaying Data Monitor Mode With Consult-II
      G00778848Courtesy of NISSAN MOTOR CO., U.S.A.
    4. Check "BRAKE SW1" indication under the following conditions.

      A/T models 

      Fig 2: BRAKE SW1 Item Indication Table (A/T Models)
      G00778846Courtesy of NISSAN MOTOR CO., U.S.A.

      M/T models 

      Fig 3: BRAKE SW1 Item Indication Table (M/T Models)
      G00778847Courtesy of NISSAN MOTOR CO., U.S.A.

    Without CONSULT-II 

    1. Turn ignition switch ON.
    2. Check voltage between ECM terminal 108 and ground under the following conditions.
      Fig 4: Checking Voltage Between ECM Terminal 108 & Ground
      G00778851Courtesy of NISSAN MOTOR CO., U.S.A.

      A/T models 

      Fig 5: Voltage Condition Table (A/T Models)
      G00778849Courtesy of NISSAN MOTOR CO., U.S.A.

      M/T models 

      Fig 6: Voltage Condition Table (M/T Models)
      G00778850Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    1. OK: GO TO 2.
    2. NG (M/T models): GO TO  3.
    3. NG (A/T models): GO TO  4.
  2. CHECK OVERALL FUNCTION-II 

    With CONSULT-II 

    Check "BRAKE SW2" indication in "DATA MONITOR" mode.

    Fig 7: Displaying Data Monitor Mode With Consult-II
    G00778853Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.