2004 Nissan-Datsun Sentra SE-RFACTORY OEM SERVICE PROCEDURE

With Consult-II

  1. Turn ignition switch ON.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Wait at least 10 seconds.

    If the result is NG, go to "DIAGNOSTIC PROCEDURE ".

    If the result is OK, go to following step.

  4. Check "COOLAN TEMP/S" value.

    If the "COOLANT TEMP/S" is less than 60°C (140°F), the result will be OK.

    If the "COOLANT TEMP/S" is above 60°C (140°F), go to the following step.

  5. Cool engine down until "COOLAN TEMP/S" signal is less than 60°C (140°F).
  6. Wait at least 10 seconds.
  7. If 1st trip DTC is detected, go to "DIAGNOSTIC PROCEDURE ".
    Fig 1: Selecting Data Monitor Mode With Consult-II
    G00777119Courtesy of NISSAN MOTOR CO., U.S.A.