2004 Nissan-Datsun Sentra Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Diagnostic Procedure

  1. CHECK FUEL FILLER CAP DESIGN
    1. Turn ignition switch OFF.
    2. Check for genuine NISSAN fuel filler cap design.

    OK or NG 

    1. OK: GO TO 2.
    2. NG: Replace with genuine NISSAN fuel filler cap.
      Fig 1: Identifying Genuine NISSAN Fuel Filler Cap Design
      G00772852Courtesy of NISSAN MOTOR CO., U.S.A.
  2. CHECK FUEL FILLER CAP INSTALLATION

    Check that the cap is tightened properly by rotating the cap clockwise.

    OK or NG 

    1. OK: GO TO 3.
    2. NG:
      1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
      2. Retighten until ratcheting sound is heard.
  3. CHECK FUEL FILLER CAP FUNCTION

    Check for air releasing sound while opening the fuel filler cap.

    OK or NG 

    1. OK: GO TO  5.
    2. NG: GO TO 4.
  4. CHECK FUEL TANK VACUUM RELIEF VALVE
    1. Wipe clean valve housing.
    2. Check valve opening pressure and vacuum.

      Pressure: 15.3 - 20.0 kPa (0.156 - 0.204 kg/cm 2 , 2.22 - 2.90 psi) 

      Vacuum: -6.0 to -3.3 kPa (-0.061 to -0.034 kg/cm 2 , -0.87 to -0.48 psi) 

      Fig 2: Identifying Fuel Tank Vacuum Relief Valve
      G00772853Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.