1985 Nissan-Datsun Sentra SE, AutomaticFACTORY OEM SERVICE PROCEDURE

Glow Plug Control Unit

  1. To test pre-glow operation, connect test lamp to Blue wire of control unit (harness connector plugged in). Turn ignition on and measure amount of time test lamp is lighted. See PRE-GLOW TEST SPECIFICATIONS table.
    PRE-GLOW TEST SPECIFICATIONS

    Coolant Temperature: °F (°C) Time In Seconds Terminal Voltage
    Below 122 (50) 12 8
    Below 122 (50) 6 10.5
    Above 122 (50) 0 0
    AFTER-GLOW TEST SPECIFICATIONS

    Coolant Temperature: °F (°C) Time In Seconds
    Below -13 (-25) 31
    68 (20) 11
    104 (40) 5
    122 (50) 0
  2. To test after glow operation, connect test lamp between the Black/White wire and White wire leading to control unit. Measure amount of time that test lamp is lit when ignition switch is turned from "START" or "OFF" to "ON" position. See AFTER-GLOW TEST SPECIFICATIONS table. Test lamp will be on continuously with ignition switch in "START" position.
  3. Test lamp will turn off during after-glow operation when glow plug voltage reaches 7 volts. Replace glow plug control unit if defective.
  4. To test glow indicator, connect a test lamp between "Orange" and "White" wires leading to grow control unit. Lamp should remain lit for approximately .5-6 seconds.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.