2018 Mitsubishi RVR ESFACTORY OEM SERVICE PROCEDURE
ASC Off Switch Continuity Check
- As shown in the illustration, connect the circuit tester to the ASC OFF switch as a single unit.
- Check the continuity when the ASC OFF switch is pressed and released.
| Item | When the ASC OFF switch is released (No operation status) | When the ASC OFF switch is pressed |
|---|---|---|
| Continuity between terminal No. 1 and No. 2 | No continuity | Continuity exists. (2 Ξ© or less) |
| Continuity between terminal No. 3 and No. 4 | Continuity exists. | Continuity exists. |