2018 Mitsubishi Eclipse Cross LEFACTORY OEM SERVICE PROCEDURE

Example Of Abnormal Waveforms

NOTE:
  1. The size of the waveform patterns differs largely, depending on the adjustment of the variable knob on the oscilloscope.
  2. Identification of abnormal waveforms is easier when there is a large output current (regulator is not operating). (Waveforms can be observed when the headlights are illuminated.)
  3. Check the conditions of the charging warning light (illuminated/not illuminated). Also, check the charging system totally.
Abnormal waveform Problem cause
Example 1
G05393699
Open diode
Example 2
G05393700
Short in diode
Example 3
G05393701
Broken wire in stator coil
Example 4
G05393702
Short in stator coil