2007 Mitsubishi Outlander LS, FWDFACTORY OEM SERVICE PROCEDURE

Configuration Function

WARNING: This page is about a different car, the 2008 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.

Using the ETACS system of scan tool MB991958, the following functions can be programmed. The programmed information is held even when the battery is disconnected.

CONFIGURATION FUNCTION CHART

Adjustment item (scan tool MB991958 display) Adjustment item Adjusting contents (scan tool MB991958 display) Adjusting contents
Hazard answer back Adjustment of the number of keyless hazard warning light answer back flashes Lock:1, Unlock:2 LOCK: Flashes once, UNLOCK: Flashes twice (default)
Lock:1, Unlock:0 LOCK: Flashes once, UNLOCK: No flash
Lock:0, Unlock:2 LOCK: No flash, UNLOCK: Flash twice
Lock:2, Unlock:1 LOCK: Flash twice, UNLOCK: Flash once
Lock:2, Unlock:0 LOCK: Flash twice, UNLOCK: No flash
Lock:0, Unlock:1 LOCK: No flash, UNLOCK: Flash once
Lock:0, Unlock:0 Without function
Dome light delay timer with door Adjustment of interior light delay shutdown time 0sec 0 second (no delay shutdown time)
7.5sec 7.5 seconds
15sec 15 seconds
30sec 30 seconds (default)
60sec 60 seconds
120sec 120 seconds
180sec 180 seconds
Door unlock mode Door lock system All doors unlock All the doors are unlocked when the driver's side door is unlocked.
Dr door unlock Only the driver's side door is unlocked when the driver's side door is unlocked. (default)
Auto door unlock by P position Auto door unlock by P position function Disable Without function (default)
Always enabled Always with function
Duration of horn chirp Horn sounding time during horn answer back Short 0.01 second (default)
Long 0.02 second
Horn chirp by keyless Horn chirp by RKE Not sound horn No horn answerback function
Lock any time The horn sounds when the lock button of keyless entry transmitter is pressed once.
W lock any time The horn sounds when the lock button of keyless entry transmitter is pressed twice. (default)
Timer lock timer Timer lock period adjustment 30sec 30 seconds (default)
60sec 60 seconds
120sec 120 seconds
180sec 180 seconds
Duration pre-alarm Adjustment of pre-alarm continue time 10 sec 10 seconds (default)
6 sec 6 seconds
Alarm With/without theft-alarm function Disable Without function
Enable With function (default)
Panic alarm switch With/without panic alarm function Disable Without function
Enable With function (default)
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.