2004 Mitsubishi Lancer EvolutionFACTORY OEM SERVICE PROCEDURE

Service Specifications

A/C SERVICE SPECIFICATIONS (LANCER)

Application Specification
Compressor Type Sanden MSC90C Scroll
Dual Pressure Switch
High Pressure Switch Off: 426.7 psi (2942 kPa); On: 341.4 psi (2354 kPa)
Low Pressure Switch Off: 28.4 psi (196 kPa); On: 32.1 psi (221 kPa)
Idle Up RPM (1) 750-950
System Oil Capacity
2.0L (2) 4.7 oz.
2.4L (2) 4.0 oz.
Refrigerant (R-134a) Capacity 16.93-18.34 oz.
Magnetic Clutch Air Gap .012-.020" (.3-.5 mm)
Resistance Of Blower Motor Resistor
LO 2.54 Ohms
ML 1.24 Ohms
MH 0.6 Ohm
System Operating Pressures (3)
High Side 138-152 psi (950-1050 kPa)
Low Side 27.6-34.8 psi (190-240 kPa)
(1) After idling for 4 minutes.
(2) Use SUN PAG 56 refrigerant oil.
(3) Specification is with ambient temperature at 77°F (25°C).
A/C SERVICE SPECIFICATIONS (LANCER EVOLUTION)

Application Specification
Compressor Type Sanden MSC90C Scroll
Dual Pressure Switch
High Pressure Switch Off: 426.7 psi (2942 kPa); On: 341.4 psi (2354 kPa)
Low Pressure Switch Off: 28.4 psi (196 kPa); On: 32.1 psi (221 kPa)
Idle Up RPM (1) 750-950
System Oil Capacity (2) 4.2-4.9 oz.
Refrigerant (R-134a) Capacity 16.93-18.34 oz.
Magnetic Clutch Air Gap .012-.020" (.3-.5 mm)
Resistance Of Blower Motor Resistor
LO 2.54 Ohms
ML 1.24 Ohms
MH 0.6 Ohm
System Operating Pressures (3)
High Side 138-152 psi (950-1050 kPa)
Low Side 27.6-34.8 psi (190-240 kPa)
(1) After idling for 4 minutes.
(2) Use SUN PAG 56 refrigerant oil.
(3) Specification is with ambient temperature at 77°F (25°C).
A/C SERVICE SPECIFICATIONS (LANCER SPORTBACK)

Application Specification
Compressor Type Sanden MSC90C Scroll
Dual Pressure Switch
High Pressure Switch Off: 426.7 psi (2942 kPa); On: 341.4 psi (2354 kPa)
Low Pressure Switch Off: 28.4 psi (196 kPa); On: 32.1 psi (221 kPa)
Idle Up RPM (1) 775-975
System Oil Capacity (2) 4.1 oz.
Refrigerant (R-134a) Capacity 16.93-18.34 oz.
Magnetic Clutch Air Gap .012-.020" (.3-.5 mm)
Resistance Of Blower Motor Resistor
LO 2.54 Ohms
ML 1.24 Ohms
MH 0.6 Ohm
System Operating Pressures (3)
High Side 138-152 psi (950-1050 kPa)
Low Side 27.6-34.8 psi (190-240 kPa)
(1) After idling for 4 minutes.
(2) Use SUN PAG 56 refrigerant oil.
(3) Specification is with ambient temperature at 77°F (25°C).
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.