2004 Mitsubishi Lancer EvolutionFACTORY OEM SERVICE PROCEDURE
Output Current Test
WARNING: This page is about a different car, the 2004 Mitsubishi Eclipse. However, it is still accessible from the selected car via links, so may be relevant.
Required special tool: MB991958: Scan Tool MUT-III Sub Assembly, MB991824: V.C.I., MB991827 MUT-III USB Cable, MB5991910: MUT-III Main Harness A. This test determines whether the generator outputs normal current. See Fig 1 .
- Before the test, always be sure to check the following.
- Generator installation.
- Battery.
- Generator drive belt tension.
- Fusible link.
- Abnormal noise from the generator while the engine is running.
NOTE: The battery to be used should be slightly discharged. The load in a fully-charged battery will be insufficient and the test may not be able to be carried out correctly. - Turn the ignition switch to the LOCK (OFF) position.
- Disconnect the negative battery cable.
- Disconnect the generator output wire from the generator B terminal and connect a DC test ammeter with a range of 0-100A in series between the B terminal and the disconnected output wire. (Connect the positive lead of the ammeter to the B terminal, and then connect the negative lead of the ammeter to the disconnected output wire.)
- Connect a voltmeter with a range of 0-20V between the generator B terminal and ground. (Connect the positive lead of the voltmeter to the B terminal, and then connect the negative lead of the voltmeter to ground.)
- Connect the negative battery cable.
- Connect an engine tachometer or scan tool MB991958.
- Leave the hood open.
- Check to be sure that the reading on the voltmeter is equal to the battery positive voltage.
- After turning on the headlights, start the engine.
WARNING:
Battery posts, terminals and related accessories contain lead and lead compounds. Wash hands after handling.
WARNING:
Never use clips to connect the line. Loose connections (for example, using clips) will lead to a serious accident because of high current.
NOTE:
A clamp-type ammeter which enables measurements to be taken without disconnecting the generator output wire is recommended.
NOTE:
If the voltage is 0 V, the cause is probably an open circuit in the wire or fusible link between the generator B terminal and the battery positive terminal or malfunctioning voltmeter.
NOTE:
Because the current from the battery will soon drop after the engine is started, the next step should be carried out as quickly as possible in order to obtain the maximum current output value.
NOTE:
The current output value will depend on the electrical load and the temperature of the generator body.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.